This document explains how to use Xcalibur Global to enable the use of an Elo touchscreen on TCs.
This procedure is based on the following steps:
TCs
Create an Xcalibur Policy that is linked to the target OU
Configure the Xcalibur Policy to enable the use of an Elo touchscreen
Applicable Software Versions
This document is based on an environment with the following installed software versions:
Xcalibur Global 1.1 Rev. 2
2007 Resource Kit v.2 & SP4
Chip PC Thin Client Firmware 6.5.5
ELO Touch Screen for Xtreme PC plug-in 1.0007
Procedure
Select the OU Containing the Target TCs
Launch the Xcalibur Global Management Console by clicking on Start > Programs > Xcalibur Global 1.1 > Management Console.
In the left pane of the Xcalibur Management Console, expand the folders under Xcalibur Directory Manager to reveal the OU that contains the target TCs. In this example expand: net8.qa8 \ Chip PC \ Thin Clients.
Figure 1: Xcalibur Management Console - Select Target OU
In the expanded folders, select the target OU (In this example Berlin).
Create an Xcalibur Policy that is Linked to the Target OU
Right-click on the target OU (Berlinin this example) to display a menu.
On the menu, click Properties to display the <OU> Properties dialog box.
Figure 2: Xcalibur Management Console – Target OU > Properties
In the <OU> Properties dialog box,select the Xcalibur Policy tab.
In the Policy Editor window, in the right pane, select and right-click Elo Touch Screen to open a menu
Figure 9: Policy Editor Window – Elo Touch Screen Settings
On the menu, click Settings to open the Elo Touch Screen dialog box.
In the Elo Touch Screen dialog box, perform the following:
Select Enabled
In the Select Port drop-down list box, select the port that the TC will use to connect to the Elo touchscreen(COM1 in this example)
Noet: If USB was selected, after completing step ý8.3, skip to step ý14.
Figure 10: Elo Touch Screen Dialog Box – Settings
Click OK to returen to the Policy Editor window.
In the Policy Editor window, expand the following path: <Policy Name>\ Device Configuration \ Peripheral Settings
Under Peripheral Settings, select Peripheral Port Settings.
In the right pane, select and right-click the Communications Port that was selected in step ý8.2 (Communications Port (COM1) in this example) to open a menu.
On the menu, click Settings to open the Communications Portdialog box.
Figure 11: Policy Editor Window - Communications Port Settings
In the Communications Port dialog box, perform the following:
Select Enabled
Select Use port for printer connection
Select Allow mapping this port into the session
Figure 12: Communications Port Dialog Box – Settings
Click OK to return to the Policy Editor window.
In the <OU> Properties dialog box, click Close to complete the procedure and return to the Xcalibur Global Management Console.
Process Outcome:
Xcalibur Global now has a policy that will enable the use of Elo touchscreens on thin clients.
The policy is linked to the OU that was selected.
The policy will affect all devices within the OU and any child OUs (as long a there are no restrictions on policy inheritance).